For disinfection of heat-sensitive instrumentation, after pre-disinfectant cleaning.
Main Features :
• Ready-to-use solution without activator.
• Checking the validity of the bath using a test strip (measurement of glutaraldehyde levels).
• Wetting power without foaming effect.
• Contact time from 15 minutes.
• Active on Clostridium difficile spores.
USE
Before use, carry out pre-cleaning or complete mechanical cleaning and intermediate rinsing of the medical devices to be treated.
When using for the first time, remove the tamper-evident ring then unscrew the cap.
1- Unscrew the cap of the can and transfer the contents into the container. Close the container after use.
2- Place opened and disassembled medical devices in the solution, ensuring that they are completely submerged. Ensure irrigation of canals if present. Cover the bin.
3- Contact time: from 15 min. according to the spectrum of activity sought.
4- Rinse carefully with sterile or filtered water before reuse.
5- Before storage, dry the devices with medical air on a previously cleaned dry surface.
For disinfection of heat-sensitive instrumentation, after pre-disinfectant cleaning.
Main Features :
• Ready-to-use solution without activator.
• Checking the validity of the bath using a test strip (measurement of glutaraldehyde levels).
• Wetting power without foaming effect.
• Contact time from 15 minutes.
• Active on Clostridium difficile spores.
USE
Before use, carry out pre-cleaning or complete mechanical cleaning and intermediate rinsing of the medical devices to be treated.
When using for the first time, remove the tamper-evident ring then unscrew the cap.
1- Unscrew the cap of the can and transfer the contents into the container. Close the container after use.
2- Place opened and disassembled medical devices in the solution, ensuring that they are completely submerged. Ensure irrigation of canals if present. Cover the bin.
3- Contact time: from 15 min. according to the spectrum of activity sought.
4- Rinse carefully with sterile or filtered water before reuse.
5- Before storage, dry the devices with medical air on a previously cleaned dry surface.